• ASTM F647-94(2006)

ASTM F647-94(2006)

Standard Practice for Evaluating and Specifying Implantable Shunt Assemblies for Neurosurgical Application

ASTM International, 09/01/2006

Publisher: ASTM

File Format: PDF

$32.00$65.00


Published:01/09/2006

Pages:12

File Size:1 file , 130 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This practice covers requirements for the evaluation and specification of implantable shunts as related to resistance to flow, direction of flow, materials, radiopacity, mechanical properties, finish, sterility, and labeling of shunt assemblies.

1.2 Devices to which this practice is applicable include, but are not limited to, those that are temporarily implanted to effect external drainage; or permanently implanted to effect shunting of fluid from a cerebral ventricle, a cyst, the subarachnoid space to the peritoneal cavity, the venous circulation, or some other suitable internal delivery site, and intracranial bypass.

1.3 Limitations Although this practice includes a standard test method for the evaluation of pressure/flow characteristics of shunts or shunt components, it does not include specific pressure/flow requirements.

1.4 The following components, that individually or in combination comprise shunt assemblies, are considered to be within the scope of this practice: catheters (such as atrial, peritoneal, ventricular), connectors, implantable accessory devices (such as antisiphon devices and reservoirs), valved catheters and valves.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 1

The following standards contain provisions that, through reference in this text, constitute provisions of this practice. At the time of publication, the editions indicated are valid. All standards are subject to revision, and parties to agreements based on this practice are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. Devices or components, or both, whose structures are comparable to that outlined in these standards are acceptable.

1.5 This test method provides the procedure and acceptance criteria upon which a judgment of acceptable radiopacity can be based and labeling claims substantiated.

More ASTM standard pdf

ASTM C1594-07

ASTM C1594-07

Standard Specification for Polyimide Rigid Cellular Thermal Insulation

$30.00 $60.00

ASTM D3670-91(1996)e1

ASTM D3670-91(1996)e1

Standard Guide for Determination of Precision and Bias of Methods of Committee D22

$29.00 $58.00

ASTM C150-07

ASTM C150-07

Standard Specification for Portland Cement

$30.00 $60.00

ASTM D5139-90(1996)

ASTM D5139-90(1996)

Standard Specification for Sample Preparation for Qualification Testing of Coatings to be Used in Nuclear Power Plants

$25.00 $50.00